反应 #4168461
相关文献 (1)
openreactiondata ↗doi:10.1039/C8SC04228D
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-5d748f15459f462898eacf8fb7a8c615暂无可渲染的结构数据
CSC1=CC=CC(=C1)N产品信息
3-methylsulfanylaniline(CAS 1783-81-9)的产品身份、结构标识及相关反应资料,供化学中间体检索、研发和采购评估使用。
可能的应用方向
仅供专业研发与工业用途
数据库编号 15693
安全提示
仅供专业研发与工业用途。操作前请依据供应商提供的安全数据表完成风险评估。
合成路线数据
12 条反应 · 12 篇文献
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-5d748f15459f462898eacf8fb7a8c615反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-6a9a1cbdef4b4c1bb32f20aa88227359反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-6df03887ebe04843aa2721da56a3cc73反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-8b7f8e76be0b4057bd3ac52af832f230反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-07f2059dc2874df7a67e7e2d1e7cc6fb反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-d83a16cd330a4a4d9903c6866b9982fb反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-17e8973003f1474daf2c966e58632134反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-1a67d173f2094060b517527550d8856d反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-effd110d58514c3882ec62b2f386c6a4反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-cd197b9afa0547a4aec3c85a0d7fe455反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-ce60680aca364e01b93d44a66c6b5734反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-70b43181a1ae44528e5d10a17737f64bPubChem References
以下资料来自该化合物的公开数据库参考记录。
相关产品
12 related records
CAS 1184030-27-0
CAS 1783-82-0
CAS 75794-20-6
CAS 137-07-5
CAS 100062-94-0
CAS 24900-69-4
CAS 463946-41-0
CAS 372-16-7
CAS 27122-82-3
CAS 1135-14-4
CAS 75464-52-7
CAS 1352311-14-8
