反应 #4108394
相关文献 (1)
openreactiondata ↗doi:10.1039/C8SC04228D
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-c86d24a8b01c494e8a5f9cf838daeb1c暂无可渲染的结构数据
CNC1=CC=C(C=C1)F产品信息
4-氟-N-甲基苯胺(CAS 459-59-6)的产品身份、结构标识及相关反应资料,供化学中间体检索、研发和采购评估使用。
可能的应用方向
仅供专业研发与工业用途
数据库编号 68024
安全提示
仅供专业研发与工业用途。操作前请依据供应商提供的安全数据表完成风险评估。
合成路线数据
12 条反应 · 12 篇文献
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-c86d24a8b01c494e8a5f9cf838daeb1c反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-08f23101365a4cdcbd882cdbf4b81eb3反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-a433892632a2473b9eaa54d4ecfa32b0反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-e569baacef0f4faf9d80cc4aa9f99bb6反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-17599f0f89f544d2988c90870dc443d1反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-e18d2e88fd8446c9a8b2bba190cf2bbf反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-a60c83c2b4b84706972999db4f8e5e2a反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-f6a53823438a402589fa7a7f71d43236反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-52e4182b05584b6e8c78b35e330fe2cc反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-d0972f7347d644ceb0d67c4dfb76f14e反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-22b22a7e7abe48fd97da031c0d189626反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-896b2c6270ee4c538e39eb129f8907bePubChem References
以下资料来自该化合物的公开数据库参考记录。
相关产品
12 related records
CAS 100-61-8
CAS 372-39-4
CAS 123685-60-9
CAS 367-31-7
CAS 107603-52-1
CAS 163733-96-8
CAS 363-81-5
CAS 348133-46-0
CAS 401567-10-0
CAS 330-91-6
CAS 62078-78-8
CAS 947255-03-0
