反应 #4109596
相关文献 (1)
openreactiondata ↗doi:10.1039/C8SC04228D
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-8bf8beb8a81a4d008501f47813525d78暂无可渲染的结构数据
CCCCN1CCNCC1产品信息
1-丁基哌嗪(CAS 5610-49-1)的产品身份、结构标识及相关反应资料,供化学中间体检索、研发和采购评估使用。
可能的应用方向
仅供专业研发与工业用途
数据库编号 424322
安全提示
仅供专业研发与工业用途。操作前请依据供应商提供的安全数据表完成风险评估。
合成路线数据
12 条反应 · 12 篇文献
反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-8bf8beb8a81a4d008501f47813525d78反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-f6ebfd9d376d47f9907ef144acbb4bde反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-0d6dbc4c627047038d8f73d916e7ca31反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-d971f875b64f4a189d102369bb02ba86反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-5c3069c0ced249c0a98d64f79eb7b62c反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-6ec7929c6ffe4a049eb35e4b4845e0c9反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-18003e7b240349109faa81235c437780反应条件: temp:0.00; pressure:0.00; stir:
来源 ID: ord-32e28bbcb760462da3b0bbbf6aa0a42f反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-048163b293674e3ea711b34f78b56fe4反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-9b2f4455068b4aa6b8eada24dcef04c7反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-8b5d6b0a4fbf4a87bc662026ab356579反应条件: temp:25.01; pressure:0.00; stir:
实验步骤: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
来源 ID: ord-a5b8d6f4e008476e8e63781b53bd3e4ePubChem References
以下资料来自该化合物的公开数据库参考记录。
相关产品
12 related records
CAS 54722-40-6
CAS 1021145-64-1
CAS 82394-26-1
CAS 115281-17-9
CAS 22763-69-5
CAS 58910-31-9
CAS 50866-75-6
CAS 91015-23-5
CAS 82394-25-0
CAS 63207-03-4
CAS 54256-45-0
CAS 54722-41-7
